Description
Hieff Canace™ Uracil+ High-Fidelity DNA polymerase, is a new generation of high-fidelity DNA Polymerase based on Pfu DNA Polymerase. The Hieff Canace™ Uracil+ high-fidelity DNA Polymerase enables rapid and accurate PCR reactions for complex templates. Its fidelity is improved significantly, and it completely avoids the amplification failure caused by using dUTP-containing primers/templates/dNTPs. The product is equipped with an optimized enzyme buffer and the addition of PCR-enhancing components, making the enzyme highly efficient and adaptable to a wide range of templates, and suitable for amplification of complex templates.
Product Components
Component number |
Components |
Cat#/Size |
||
14384ES03 |
14384ES08 |
14384ES50 |
||
14384-A |
Hieff Canace™ Uracil+ High-Fidelity DNA Polymerase (3 U/μL) |
1 mL |
5 mL |
50 mL |
Shipping and Storage
The components are shipped with ice packs and can be stored at -20°C for 1 year.
Product Application
High-fidelity library amplification using dUTP-containing primers/templates/dNTPs.
Cautions
1. For your safety and health, please wear lab coats and disposable gloves for operation.
2. For research use only!
Instructions
Hieff Canace™ Uracil+ High-Fidelity DNA polymerase is used in a slightly different way than conventional high-fidelity enzymes. Please read the instructions carefully before use.
1. Recommended reaction system
All operations should be carried out on the ice. 2×CanaceTM Uracil+ PCR buffer should be well mixed after thawing. Before the system configuration, please preheat the PCR instrument. After the addition of the components, mix the sample well by a pipette and spin it down to the bottom of the tube, then place it in the preheated PCR instrument for amplification. After use, return all components to -20 °C for storage.
Table 1. PCR amplification reaction
Components |
Volume |
Template or ligation product |
X µL |
2×CanaceTM Uracil+ PCR buffer (containing Mg2+, dNTPs) (Cat#15423) |
25 µL |
Forward primer (10-25 μM) |
1-2.5 µL |
Reverse primer (10-25 μM) |
1-2.5 µL |
Hieff CanaceTM Uracil+ High-Fidelity DNA polymerase (3 U/µL) |
1 U |
ddH2O |
Total to 50 µL |
[Notes]:
1)Reagents: Sufficiently thaw each component before use;
2)Templates: The use of purified high-quality DNA templates can significantly improve the efficiency and success rate of amplification;
3)dNTPs: The recommended final dNTPs concentration is 200 μM. The dNTPs provided in the kit do not contain dUTP. If special circumstances require the preparation of dUTP-containing templates, additional dUTP can be added to a final concentration of 400 μM.
4)Polymerase concentration: 1 U/50 μL is recommended. It can be optimized between 0.5-2 U/50 μL, does not exceed 2 U/50 μL. In order to prevent the polymerase from degrading primers due to 3 '→5' exonuclide activity, it is suggested to add polymerase to the reaction system in the last step.
5)Mg2+ final concentration: The final concentration of the system is 2 mM. Please ask our company to provide a buffer with low Mg2+ concentration or without Mg2+ if you have special needs.
2. Recommended reaction procedure
Table 2. PCR amplification reaction procedure
Step |
Temperature |
Duration |
Number of cycles |
Initial Denaturation |
98°C |
1 min |
1 |
Denaturation |
98°C |
10 sec |
1~15 |
Annealing |
60°C |
30 sec |
|
Extension |
72°C |
30 sec |
|
Final Extension |
72°C |
5 min |
1 |
Hold |
4°C |
- |
- |
[Notes]:
1) Initial denaturation temperature and time: 98℃ is recommended. The recommended time is 30 sec for simple templates such as plasmid DNA, 1 min for libraries, 3 min for complex templates such as cDNA and genomic DNA, and 5-10 min for high GC content templates.
2) Annealing temperature and time: 60℃ is recommended, or a temperature gradient can be set up to find the optimal temperature for primer annealing according to needs. The recommended annealing time is 20 sec and can be adjusted within 10-30 sec. Too long an annealing time may lead to dispersion of the amplified products on the gel.
3)Extension temperature and time: 72℃ is recommended. The extension time is adjusted according to actual needs.