Description
The p24 antigen is a major core structural protein of the HIV-1 virus. Since the p24 antigen appears earlier in the body than viral antibodies, it can be used to detect and determine HIV infection at an earlier stage. Additionally, in biomedical research, the lentiviral vector is commonly used to deliver target genes into cells, and measuring the p24 antigen is a method to assess the transduction efficiency of lentiviruses.
The Yeasen Human HIV-1 p24 ELISA (Enzyme-Linked Immunosorbent Assay) Kit is an in vitro enzyme-linked immunosorbent assay kit designed for the quantitative determination of HIV-1 p24 in serum, plasma, and cell culture supernatants. Specific anti-HIV-1 p24 antibodies are pre-coated on high-affinity enzyme-labeled plates. After adding standards and test samples to the wells of the enzyme-labeled plate and incubating, any HIV-1 p24 present in the samples binds to the solid-phase antibodies. After washing away unbound substances, a detection antibody is added and incubated. Following another wash, an enzyme conjugate (Streptavidin-HRP) is added and incubated. After washing, a chromogenic substrate (TMB) is added, and the plate is incubated in the dark. The intensity of the color reaction is proportional to the concentration of HIV-1 p24 in the sample. The reaction is terminated by adding a stop solution, and the absorbance is measured at 450 nm wavelength (with a reference wavelength of 570 - 630 nm).
Cat.No. |
99301ES48 / 99301ES96 |
Size |
48 T / 96 T |
Detection Range |
15.63-1000 pg/mL |
Detection Method |
Sandwich ELISA |
Detection Time |
4.5 hours |
Sensitivity |
2.7 pg/mL |
Dilution Linearity |
84 - 125% |
Recovery Rate |
81 - 122% |
Intra-assay Variability |
4.6% |
Inter-assay Variability |
6.0% |
Components
Components No. |
Name |
Storage Temperature |
99301ES48 |
99301ES96 |
99301-A |
Plate |
2~8℃ |
48 T |
96 T |
99301-B |
Standard |
2~8℃ |
2 tubes |
4 tubes |
99301-C |
Detection Antibody |
2~8℃ |
120 μL |
240 μL |
99301-D |
Enzyme Conjugate |
2~8℃(Avoid Light) |
30 μL |
60 μL |
99301-E |
Sample Dilution Buffer |
2~8℃ |
8 mL |
15 mL |
99301-F |
Antibody/Enzyme Dilution Buffer |
2~8℃ |
15 mL |
30 mL |
99301-G |
20x Wash Buffer |
2~8℃ |
25 mL |
50 mL |
99301-H |
Substrate Solution |
2~8℃(Avoid Light) |
8 mL |
15 mL |
99301-I |
Stop Solution |
Room Temperature |
5 mL |
10 mL |
99301-J |
Plate Sealers |
Room Temperature |
3 pieces |
5 pieces |
Product Storage
The assay kit can be stored at 2-8℃. Alternatively, the reagents can be stored according to the storage conditions provided in the component information to avoid contamination and repeated freeze-thaw cycles. Diluted working solutions should be used immediately and not reused. The shelf life is 1 year.
Table 1. Reagent Storage Table After First Use
Material Name |
Storage Conditions |
Plate |
Unused strips can be returned to the aluminum foil bag, tightly sealed, and stored at 2-8°C to avoid moisture absorption. |
Standard |
Use within 48 hours after dissolution, store at 2-8°C to avoid contamination. |
Detection antibody |
Use within 48 hours after dilution, store at 2~8°C to avoid contamination. |
Enzyme conjugate |
|
Sample Dilution Buffer |
Store at 2~8°C for 1 month, avoiding contamination. |
Antibody/Enzyme Dilution Buffer |
|
20x Wash Buffer |
|
Substrate solution |
Store at 2~8°C for 1 month, avoiding light exposure. |
Stop solution |
Can be stored at room temperature. |
Plate Sealers |
Instructions for use
1.For quantitative detection of HIV-1 p24 content in serum, plasma, and cell culture supernatant.
2. Please read the instruction manual carefully before using this product.
Operating precautions
1. This product is for research use only.
2. For your safety and health, wear laboratory clothing and disposable gloves when operating.
3. The reagent kit should be used within the shelf life. It is prohibited to mix reagents from different batches.
4. This product can only be used to detect target antigens and samples as indicated in the instruction manual. Other applications require validation by the user, and the reliability and accuracy of the use should be evaluated based on the results.
Do not mix or substitute reagents or materials from different batches or suppliers of other kits.
Documents:
Safety Data Sheet
Manuals
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Inquiry
You may also like
FAQ
The product is for research purposes only and is not intended for therapeutic or diagnostic use in humans or animals. Products and content are protected by patents, trademarks, and copyrights owned by Yeasen Biotechnology. Trademark symbols indicate the country of origin, not necessarily registration in all regions.
Certain applications may require additional third-party intellectual property rights.
Yeasen is dedicated to ethical science, believing our research should address critical questions while ensuring safety and ethical standards.